Name : Rack Mount Telecom Rectifier System
Rectifier Module : 1.74KW*3pcs
Controller : Ethernet , SNMP, ModBus and RS485 communication
Output Voltage : -48VDC (-43 to -58VDC)
Iutput voltage : 220VAC Single Phase
Application : telecom,utility,Industrial Automation,Electric Power Transmission,BTS
AC Input DC Output 19-Inch 2U Standard Rectifier Power System For Telecom Cabinet
1. AC Input DC Output 19-Inch 2U Standard Rectifier Power System For Telecom Cabinet Introduction:
The 2U Standard Rectifier Power System has been specifically designed to meet the demand for higher density and more compact power solutions. It is suitable for applications needing an expandable, easily serviceable and reliable power supply, fitting within a minimal space..
M45D65B consists of distribution unit, rectifier module, conversion module, monitoring module. The standard as table below:
Configuration | Rectifier module | Remark |
Standard | GB 4943 | For details, please refer to the specifications of modules |
Standard | IEC/EN 62368-1 | |
Standard | EN 55032 Class A,GR1089 Issue 4 ,R3-10, R3-11, R3-12 Class B certified by North America | |
Standard | EN300386,CLASSA |
2. U 24KW Rectifier System Quick Details:
AC Distribution | DC Distribution | ||
Input Mode | 380VAC three-phase | Output Voltage | 42 to -58VDC,rated value:-53.5VDC |
Input Capacity | 63A | Load Breaker | 6×30A/ 1 P |
Input Frequency | 45 to 66Hz,rated value:50Hz/60Hz | SPD | 10kA, 8/20μs |
Rectifier | Controller | ||
Input Voltage | 85VAC~300VAC,rated 220VAC | Alarm output | 6 dry contact |
Efficiency | >96% | Signal input | 4 AI(3 Battery temp.,1ambient temp),7 DI (SPD,6 common DI) |
Rated Power | 1740W(176-300VAC) | Communication Port | RS485,SNMP |
Working Temperature | -40℃~+75℃(fuly output below 50℃) | Display Mode | LCD |
System | Environment | ||
Cooling Mode | Natural cooling | Operating Temperature | 10℃ to +55℃ |
Cabling Mode | Back wiring | Storage Temperature | 40℃ to+75℃ |
Maintenance Mode | Backend maintenance,support module grade change | Operating Humidity | 5%to 95%(non-condensing) |
Protection Level | IP20 |
Altitude | 0 to 4000m(if the altitude is within the range of 3000m to 4000m,the maximum operating temperature decreases by 1℃ as the altitude increases by 200m) |